Screw terminals
Connector | Function |
1-2 | AUX relay (NO/NC) |
3-4 | Supply voltage (12-35 VDC) |
8-9 | Exit button * |
8, 10 | Door contact ** |
The 120Ω resistor (supplied) is only used when the reader is connected to a door controller.
* Closing the open button input means that the lock is unlocked for the corresponding time (plus the set opening time).
** When using the door contact, the opening relay returns to the locked position, regardless of the opening time, as soon as the door is opened. Closed door is indicated by a closed contact.