Programming
The programming mode is entered by pressing the programming button (the rightmost round button) and entering of the programming code. (Default set to 112233).
Factory default settings are highlighted in bold.
An Excel programming template can be downloaded from:
www.info.axema.se/download/A66_programmeringsmall.xlsx
Remember to replace the programming code with a self-selected 6-digit code.
Menues

- Time / date, setting the time and date.
- Time schedules, programming of up to three time schedules with three intervals per day.
(i.e, schedule for daily unlocked: 08:00-12:00 and 13:00-16:00 during weekdays. Bistable safety level is not available with A66 in stand-alone mode. - )
- Opening hours, number of seconds the door is unlocked at a valid access (001-999 (16 min 39 sec)). (007)

- New code, add a new code and select a time schedule during which it is active, alternatively always can be selected.
- Change code
- Delete code
To change the time schedule for a code, delete the code and add a new code.

- New tag, add a tag or radio key by reading or by ID number.
- Series installation, programming of tags in ID number sequence (EM) with the first and last tag in the series. Tags are programmed with the keypad or by reading.
- Remove tag, tag removal can be done in different ways.
- By reading under Show tag,
- With position number under Enter position.
- With ID number under Enter number.
- and from list.
- Time schedule tag, choice of time schedule when access tags should be eligibel.
- Schedule PIN + tag, choice of time schedule when access tags, in combination with PIN code, must have authorization. PIN code is selected the first time the access tag is used.

- Day open Selecting a time schedule during which the door should be unlocked, alternatively, Always, or Never can be selected.
- Exit button Selecting a time schedule when the exit button should work, Always, Never or according to schedule. The door remains unlocked as long as the exit button is pressed and the opening time does not start until the button is released.

- Reversed Lock Function, Activate/Deactivate
- Reversed Lock Function, Activate/Deactivate
Activated when selecting one or more channels.- PostNord, SDR, the economic crime authority and Police
- Bring, Citymail and Pressens morgontjänst
- Not used
- Advertising, real estate agencies.
- The Swedish Enforcement Agency.
- Testing, service and installation
- RF-transmitter (Radio keys), Activate/Disable Each button for RN18-4 is activated separately. Button A applies to RN18-FM and RN18-1.
- MIFARE Activate/Deactivate
- EM, Activate/Deactivate
- Backlight Activate/Deactivate
To activate constant maximum backlight, press and hold button 6 for three seconds, then release with return arrow. - Sound, key presses, OFF, Low, Medium, High
- Programming code, Set a new programming code (112233)
- Daylight saving time Activate/Deactivate
- Language, selecting the language. (Swedish)
- Operating mode (For selection of possible SOLO function)
- Factory reset