Maintenance of SOLO systems

When DESFire EV2 chips are used in the system, data is spread to slave readers automatically.

The database must be synchronized manually, using programming chip (s):
- If the system has readers whose users do not pass the master reader
- When the cards and tags used in the system are of the EM or MIFARE Classic type

Synchronisation of all readers.

Programming tag refers to a DESFire EV2 tag added to the system after the master reader was configured as a master.

A minus sign (-) at the top of the master reader display means that the database is not consistent across the system's readers. Take action by: (Repetition may be required.)

  1. Show the programming tag for the master reader.
  2. Display the programming tag to all slave readers.

A plus sign (+) appears at the top of the master reader's display when the database is synchronized in all readers.

Updated27/02/2024