5.00.0001

Released 2023-14-12

- Updating must be carried out by an installer with knowledge of the particular VAKA system.

- Updates must be made on site.

- Before updating to a new VAKA version, it is important to ensure compatibility with integrated third-party solutions * . Examples of such solutions are Renz mail boxes and Amido Alliera. To avoid operational disturbances, check with respective party that applicable versions are compatible.- Before updating, ensure that system security is set to the default level (Settings->System->Security).

- After updating, it can take up to 45 minutes before the system is fully operational.

* For VAPI integrations against third-party systems, note that VAKA 5.00 requires at least VAPI 5.0.1.

What is new?

VAKA Online*

From VAKA 5.00 there is functionality to connect the VAKA system to VAKA Online.

In VAKA 5.00, the Accessy integration can be activated, which allows door unlocking from mobile application.

*VAKA Online requires that the VAKA system is equipped with a domain controller B60.

VAKA Admin

  • Added support for connecting the VAKA system to VAKA Online.
  • Added functionality to remotely unlock door through VAKA Online.

Booking

  • Improved log-in page to booking portal to better manage small screens.

Java/PC-Client

  • Added possibility to set sound volume for sound module C12, without a reader having to be connected to the door controller.
  • Improved import function.
  • Added column for Domain in import/export file.
  • Added role settings for VAKA Online.

Other

  • Added functionality to indicate in unsetting of alarm when using monostable alarm control. During unsetting of the alarm, unintentional setting is prevented.

Compatibility

VAKA Admin

VAKA Admin is verified to work with the following browsers:

  • Apple Safari: 15.6.1
  • Google Chrome: 118.0.5993.71
  • Microsoft Edge: 117.0.2045.60
  • Mozilla Firefox: 118.0.2

Java/PC-client

The Java/PC client has been verified to work with these versions:

  • JRE 8: Eclipse Adoptium openjdk 1.8.0.272.
  • JRE 11: openjdk 11.0.20.1
  • Webstart alternative (JNLP File): OpenWebStart 1.8.0 & 1.9.0

Update information

Before updating to VAKA 5, the system must be at least version 3.86, 3.87 or 3.88. In case the system is in older version, follow previous update instructions to upgrade to any of the 3.8 versions.

For questions and for help with updating, please contact technical support, +46 (0)8-722 34 40, button selection 2 or [email protected].

After upgrade, the following versions apply

 

Product Version Showed in
B60 5.00.0001 System diagnostics
B05, B06, B15, B16, B17, B17-R, B25, B26, B27, B27-R 5.00.0001 System diagnostics
B28, B18 5.00.0001 System diagnostics
PC-client 5.00.0001 (presented as 5.00.1) VAKA window
Info- and booking panel 5.00.0001 Configuration menu in panel
A6x (HW:2)   System diagnostics as A66:
A6x (HW:1)   In system diagnostics as A66.
A6x (HW:0) 1.07.01 In system diagnostics as A66
A45   System diagnostics
A42, A52, A53, A56   System diagnostics