About AUX relay functions

A66, B27, B27-R and B28 have programmable AUX relays for various local or global functions in Axema VAKA.

B27, B27-R and B28

Relay functions Function
Door opener The relay is closed when the door opener is active. See Door opener and extended unlocked time.
Local alarm event The relay closes when an alarm event is generated for the door.
Global alarm event The relay closes when an alarm event is generated in the domain.
Gate control See VAKA Installation examples (www.info.axema.se?vaka).

A66

Relay functions Function
Locks Lock relay, normally open contact (NO)
Reversed Lock Function Lock relay, normally closed contact (NC)
Camera The relay closes on calling and speaking on the entry phone.
Door opener The relay is closed when the door opener is active. See Door opener and extended unlocked time.
Alarm The relay closes if the door is open after an unlocked period and warning period.
Warning The relay closes if the door is open after an unlocked period.
Gate control See VAKA Installation examples (www.info.axema.se?vaka).

Updated 20/03/2023