Door opener and extended unlocked time

Special accessibility, such as door opener control settings and extended unlocked time, is done for each door. Door opener control and extended unlocked time are enabled for each access group.

Door opener

Door opener can be linked to door controller VAKA B28 or VAKA Reader A66.

Door opener control linked to door controller

If a door opener is connected to the door controller, select Door Opener Control in Doors -> Current door -> Devices -> Aux. relay.

Door opener control connected to A66

If a door opener control is connected to Reader VAKA A66, navigate to Doors -> Current door ->Terminals and click the terminal connected to the door opener control. Then select Door opener as Relay function.

Delayed Door opener

If delayed activation of door opener control is required, enter this in Doors -> Accessibility-> Delayed door opener control.

Door opener using Exit button

To enable door opener control for opening using the exit button, select the appropriate periods in Doors -> Current door -> Time Control-> Remote Open: -> Enable door opener control in:. Note that the door opener must be enabled for the same periods of time. (Doors -> Time control-> Remote opening: -> Remote opening functions under:)

In the Devices tab, deselect Impulse triggered and select Enable door opener control when the remote exit button is held in for a short while if this is required.

Extended unlocked time

Extended unlocked time is set in Doors -> Current doors ->Accessibility.

Extended unlocked time using exit button

To use extended unlocked time for opening using the exit button, select the appropriate periods in Doors -> Current door-> Time Control-> Remote Open : -> Use extended unlocked time.

Note that the door opener must be enabled for the same periods of time. (Doors -> Current doorr -> Time Control-> Remote Open: -> Remote Open functions under:)

Access groups

To enable Extended unlocked time and/or Door opener control for the access group in question, select Extended unlocked time and/or Enable door opener control in Access Groups -> Privileges and Functions -> Accessibility:.

The settings for the access group do not impact opening using Smart Calls.

Updated 18/09/2023